CARATTERISTICHE TECNICHE
|
|
|
Surfix® easy |
Pocket- Surfix® |
Surfix® |
Surfix® Pro |
|
Model |
Gauge
with integrated probe |
Gauge
with integrated probe |
Gauge
with separate probe |
Gauge
with separate probe |
|
Range for steel and
non-ferrous metals |
steel:
3.500µm/140mils |
1.500µm/60mils |
1.500µm/60mils |
1.500µm/60mils |
|
Non-ferr. metals: 3.000
µm/120mils |
|
Tolerance |
3% |
1% |
1% |
1% |
|
Pole-tip: tungsten carbide |
• |
• |
• |
• |
|
Factory calibration |
• |
• |
• |
• |
|
ZERO-Averaging for higher
accuracy |
• |
• |
• |
• |
|
Calibration methods |
1-point |
2-point |
2-point |
6
various calibration methods for optimal accuracy |
|
Statistics (number, mean, std.
dev., max., min) |
• |
• |
• |
• |
|
Resistant against acids,
alkali, solvent, oil etc. |
• |
• |
• |
• |
|
Calibration with standards |
|
• |
• |
• |
|
Zero-Offset (Subtraction of a
constant value from the reading) |
|
• |
• |
• |
|
Selectable limit values |
|
• |
• |
• |
|
Operating instructions via
display |
|
• |
• |
• |
|
Readings memory |
|
80
readings |
80
readings |
10.000
readings in 250 batches |
|
Saving of the calibration
values in data files |
|
|
|
• |
|
Interface |
|
Infrared |
Infrared |
Infrared
and RS232-cable |
|
Display with backlight |
|
• |
• |
• |
|
Selectable languages |
|
• |
• |
• |
|
Continuous measurement |
|
|
|
• |
|
Maximum surface temperature of
test object |
60°C/140°F |
80°C/175°F |
150°C/302°F |
150°C/302°F |
|
(optional 300°C/572°F) |
|
Print out of date and time |
|
|
|
• |
|
Optional probes |
|
|
|
90°
FN-probe, 10 mm F-probe |
|
Inclusive PC-software
|
|
|
|
• |